Variable Speed Drive Triol AK06 narrows Harmonic Distortion down

05/10/2016

Triol AK06 VSD offers a broad range of control modes, features, options, and packaging, for use in factory automation processes and industrial OEM machines. Triol AK06 VSD with active harmonic filter (AHF) comes as an optimal solution for the efficient operation of oil companies.

Such elaboration is useful for petroleum production; it’s intended to reduce harmonic distortions in the network caused by work of 6-12-pulse rectifiers of VSD. Triol AK06 VSD with AHF includes the full functional management of ESP, compatible with different submersible motors (Induction, PMM, Linear), it is designed to protect downhole installation of the ESP series from 80 to 1700 kVA. High-powered semiconducting converters have negative effect on the main supply in connection with a non-sinusoidal current consumption. It distorts the form of the current consumption to 40%, while the power factor decreases to 0,8%. This leads to the reactive current consumption and excessive heating of supply conductors. Integrated input and output filters allow you to have a quick start of work installation as well as to provide high-quality of supplying voltage for network. A period of engine service reaches the same values as when runs directly from the mains. Active filtration generates ac signal that is back of harmonic distortion.

It affords to get sinusoidal current consumption and eliminate additional losses in heating the supply conductors. As a result, current consumption is obtained a form close to sinusoidal with harmonic reducing from 30% to 5%. A tendency like this is fully compliant with IEEE519 standard. Triol Variable Speed Drives have defined capability to withstand voltage and current waveform distortion. The latest IEEE standard 519 defines harmonic distortion limits acceptable on the input side to the AC power system.

Harmonics may be greatly magnified by power factor correction capacitors. Supply system inductance can resonate with the capacitors at some harmonic frequency, causing large currents and voltages to develop. This may damage equipment. In addition, since the impedance of a capacitor decreases with increasing frequency, capacitors tend to act as sinks for higher-order harmonics.

Triol AK06 VSD is space-saving and high-powered equipment. It provides uninterrupted control algorithms on the set of asynchronous and brushless motors, minimizes the distortion of the mains supply and ensures minimum wear of downhole equipment. Using this installation is useful for oil companies where the generator power should be full used either reduced losses from current harmonics and reactive currents.

Triol AK06 VSD with AHF is a new solution for efficient protection of the whole system from grid outage by reducing a network load.

News
Triol Webinars: LESP –…

01/08/2018

Oil&Gas industry has always been one massive field for innovative and unique developments to offer.…

We Are Waiting for…

30/07/2018

SPE Artificial Lift Conference and Exhibition 2018 is coming soon and we are as always…

Controlling Energy of the…

25/07/2018

Solar energy is a great resource granted by nature to the people with no charge.…

Triol Webinars: Be Ready…

Oil production is a difficult and expensive procedure. From year to year, the situation is…

Triol Solutions for Elevator…

23/07/2018

Lifting mechanisms enclose multiple varieties of modifications. Today they are widely spread in the most…

Multifunctional solution for industrial…

18/07/2018

Developing new products, Triol experts are always focused on creating a multifunctional and adaptive solution…

Time Proved Approach: Triol…

16/07/2018

How is a common production flow set up? The digital age is a dynamic and…

General comments:

Leave a Reply

Login with: 

Comments from Facebook: