Downhole measuring system Triol ТМ01–06

Triol ТМ01–06 downhole sensor system can be easily integrated in the dual ESP installation. It operates under the pressure of 500 atm (7 348 psig). The use of this downhole system provides total control and safe operation of the dual ESP installation, increases nonfailure operating time and reduces energy consumption on the fluid lifting.

  • Stainless steel corrosion-resistant downhole unit;
  • Downhole unit operational pressure up to 400 at;
  • Reservoir fluid temperature 150 °С;
  • ESP upper front part winding temperature up to 200 °С;
  • ESP oil pressure;
  • Operates with dual ESP installations.
ESP’s temperaturefrom 0 to + 200 ° С ± 1%
Base oil temperaturefrom 0 to + 150 ° С ± 1%
Pressurefrom 0 to 400 atm ± 1%

Surface unit ТМ01-06:

Supply voltage220 V ± 50 %
Supply frequency50/60 Hz ±2 %
Power consumption40 W
Ambient temperaturefrom – 60 to + 75 °С
Relative moisture level at 25 °C100 %
Altitude above sea level1000 m
Enclosure protection levelIP21
Operating modecontinuous
Size212 mm х 240 mm х 142 mm
Weihgt6 kg

Downhole unit ТМ01-06:

Ambient temperaturefrom 0 to + 150 °С
Motor oil temperature in ESMfrom 0 to + 200 °С
Motor winding temperaturefrom 0 to + 250 °С
Maximum pressure400 atm
Nominal depth3500 m
Enclosure protection levelIP68
Operating modecontinuous
Size:
Diameter
Length
117 mm
853 mm
Weight45 kg