Critical loads stay supplied when the grid fails.
Grid-to-island transfer
≤ 20 ms in total, with PRIME-APCS
Switching
Semiconductor, no mechanical delay
Reconnection
Synchronized, without interrupting loads
Sizing
Rated for the critical load of the site

Discover how one switch keeps critical loads running through grid faults and brings them back without a restart.
Semiconductor switching separates the site from a faulty grid, and PRIME-APCS takes over the loads in grid-forming mode.
Watches the grid at all times and detects loss of voltage, dips, and frequency and phase deviations.
Closes only after voltage, frequency and phase are matched, so the loads go back to the grid without interruption.
Keeps critical feeders supplied and separates non-critical feeders when needed.
Coordinates with grid protection and anti-islanding requirements at the connection point.
A built-in bypass for maintenance of the switch.
Rated for the critical load of the site and matched to the power of PRIME-APCS, with total grid-toisland transfer within 20 ms.
your reality, your challenges, your success.
Submit your request or question, and our team of specialists will contact you.
Our sales team will contact you as soon as possible.

Built through partnership. Proven by engineering. Trusted in the toughest conditions. Full-cycle production. Total reliability. Systems that perform where others fall short.
Meet our team
Meet the team behind innovations that drive industries forward. Engineers, designers, and experts turning challenges into solutions.
Triol’s partners
We collaborate with leading Oil & Gas and industrial companies worldwide to deliver efficient, proven solutions tailored to their unique challenges.
Sustainability
Because real sustainability starts at the design table - not at the marketing one - we engineer systems that conserve, protect, and outperform over time.
Technology
Where others deliver equipment, Triol delivers systems. Modular, intelligent, and field-ready. Built for the complexity of modern industry.
Implementations
Global reach, industrial depth: Triol systems implemented across continents and critical sectors.
Type
Static (semiconductor) transfer switch
Function
Connects the site busbar to the grid; grid-to-island transfer
Grid monitoring
Voltage loss, dips, frequency and phase deviations
Feeders
Separation of critical and non-critical feeders
Protection
Coordination with grid protection and anti islanding
Sizing
Rated for the critical load of the site, matched to PRIME-APCS power
We are fast where others are slow, flexible where others are rigid, and committed where others are distant.